5 -
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
 Parts catalogue
 Important
Bold reference numbers in this section identify parts not shown in the figures alongside the text, but which can be found in the exploded view diagram.
Description of the Ducati Diagnostic System instrument
The Ducati Diagnostic System (DDS) is used for diagnosis of the injection-ignition system via a serial connection. The system is also equipped with functions to test various devices on the motorcycle. The DDS tester can be used to measure current and voltage on any electrical device, to perform tests on individual components and to measure pressure and temperature values.
The DDS tester (1) is comprised of a palmtop display unit (A), a BBAD self-diagnosis module (B) and a display memory card (C).
The touch-screen display unit (A) serves for both data display and input, using the stylus housed on the side of the unit.
The self-diagnosis module (B) enables communication between the DDS tester (1) and the motorcycle’s on-board electronic control unit (ECU).
The user interface software resides in the display memory card (C) which is housed in the palm-top display unit (A).
The display unit is equipped with two connection panels: one at the top of the instrument and one at the bottom.
The top connection panel has 6 connection sockets with the following functions:
-
-
-
-
-
The bottom connection panel has 3 connection sockets with the following functions:
-
-
-
You can connect a printer to the DDS tester (1) to print test reports: connect the printer to the serial port (COM1) (G) located on the top connection panel of the tester (1).
Technical data
Power supply:
-
-
Components supplied with the DDS tester
The DDS tester (1) is supplied in a kit together with the following items:
-
-
-
-
-
-
-
-
Tester power supply
The DDS tester (1) may be powered in any one of the following ways:
-
-
-
from the tester's internal battery: the battery (Q) is housed in the top part of the tester. To operate the tester (1) using the internal battery and to recharge the battery, refer to the “User Manual” supplied with the DDS tester.
To switch on the display, press the button (T).
Connection to motorcycle
The tester requires a power supply of between 9 and 16 Volts D.C.
When using the tester, take care never to allow the power supply to fall below the minimum voltage: this situation could occur during engine starting and idling on motorcycles in which the battery is not in perfect working order. If the tester detects a power supply voltage of less than 9 Volts, the current procedures will be aborted; when the voltage returns to within the acceptable tolerance limits the procedure must initiated again from the beginning.
The DDS tester (1) may be powered from the motorcycle in any one of the following ways:
-
-
connect the power and diagnostic cable (2) to the diagnostic connection socket (P) on the tester; then connect the battery socket adapter (8) to the connection socket (R) on the power and diagnostics cable (2) and to the motorcycle battery.
 Notes
For connection of the various devices required for self-diagnostic procedures, consult the instruction handbook supplied with the tester.
DDS tester
The main functions of the DDS tester can be summarised as follows:
-
-
-
Active diagnostics. Activation of ignition-injection system transducers to test functionality and control signals (fuel pump, ignition coils, rev counter, injectors, etc.). With this function it is also possible to enter the code to override the immobilizer.
-
Road test. Allows the technician to store engine parameters recorded within a previously specified engine speed range interval. The resulting parameters can then be analysed and displayed once they have been acquired.
-
With specific sensors connected, the DDS tester can read electrical voltages, current, temperature, timing belt tension, and pressure values (lubrication and fuel supply circuits for example).
Checking and adjusting timing belt tension
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 Notes
This operation, which is performed using the DDS tester, has the advantage that it can be carried out on both timing belts with the engine still installed on the frame. An optical reader is connected to the DDS tester. The optical reader has a green LED that serves to determine that the reader is correctly positioned in front of the belt to be tested. It is also equipped with an infrared transmitter (A) and receiver (B) designed to detect oscillations of the belt when caused to vibrate with the flick of a finger.
 
Remove the spark plugs.
Position the crankshaft so that the piston of the horizontal cylinder is at TDC of its power stroke.
This is achieved by aligning the timing mark (C) on the timing driveshaft pulley (19) with the reference notch (D) on the clutch-side crankcase cover (20).
Take the measurement on section (21) of the horizontal belt as described in the paragraph “Measuring timing belt tension”.
Turn the crankshaft through 270° in the direction of rotation of the engine (so that the piston of the vertical cylinder is at TDC of the power stroke) and repeat the procedure used for the horizontal cylinder, measuring the tension on section (25) of the vertical cylinder timing belt.
Remove the belt tension sensor and disconnect the DDS tester from the motorcycle.
 
Measuring timing belt tension
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (Measurement Module) (3) to the measurement module connector (F) on the DDS tester (1).
Connect the belt tension sensor (15) to the connector (V) of the power and diagnostics cable (Measurement Module) (3).
Fix the mounting bracket of the belt tension sensor (15) using the timing belt cover bolt (22).
Aim the central green LED of the sensor (15) at the mid-point of the belt run, with the reader parallel to the belt and at a distance of about 1-1.5 cm from it.
On the DDS tester (1), select the “Measurement module” function by pressing the corresponding icon; then press the “Belt Tension” icon followed by the “Start” icon to access the “Mechanical belt tension” screen.
The socket to which the cable (Measurement Module) (3) is to be connected is indicated on the screen with a capital letter: A, B or C.
Flick the belt lightly with your finger and read the frequency value (Hz) on the DDS tester.
 Notes
Do not flick the belt several times repeatedly, as the minimum time necessary for the DDS tester to take a reading is 1 second.
 
Correct tension values are as shown in Section C 1.1, Timing system/valves and must be checked with the engine cold: apply the installation values when fitting a new belt, and the reset values when belt tension reaches 70 Hz.
 Warning
The timing belts can become slack during normal operation. When checking belt tension, if the reading is less than 70 Hz, adjust the tension to the specified values (Sect. C 1.1, Timing system/valves).
 
If the tension is incorrect, increase or reduce belt tension by loosening the nut (24) and moving the adjustable tensioner pulley (23).
Tighten the nut (24) securing the tensioner pulley.
Re-check the timing belt tension.
Repeat the above procedure until the correct belt tension is obtained.
Once finished, tighten the nut (24) of the tensioner pulley (23) to the specified torque (Sect. C 3, Engine torque settings).
Resetting the throttle position sensor (TPS)
The linear throttle potentiometer has no facility for positioning adjustment: to ensure that the system functions correctly, proceed as follows:
 Warning
This procedure must precede the first start-up of the vehicle after replacement of the throttle body, the ECU or the wiring.
 
 
Make sure the butterfly valve is seated against the stop (throttle twistgrip fully closed).
In this position you can teach the ECU the angle of the position sensor. To do this, use the DDS tester and follow the procedure described below.
 
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (2) to the diagnostics connector (A) on the tester and to the diagnostics socket (B) on the motorcycle.
Enter the general functions menu by pressing the icon “Menu 1” (C).
Press the “Select vehicle” icon and, on the next screen, press the “Select motorcycle” icon; select the motorcycle model and confirm, then select the version and confirm.
Press the icon “Select system” to display a list of the bike’s systems that can be analysed.
Select “Engine electronics” and press the “Confirm” icon (D). Next, press the “Self-diagnosis” icon to access the corresponding function.
The DDS tester will interrogate the electronic control unit and display the parameters analysed with their relative values.
 Notes
Make all connections with the motorcycle ignition key in the OFF position.
 
Press the “Settings” icon to display the special parameters.
Select the option “Reset TPS” and then press the icon “Apply”.
On completion of the operation, the message “Was the operation was completed successfully?” will appear; press “Confirm” (D).
If any problems were encountered during the operation, the tester will display the relative error messages: each message must be confirmed, (by pressing the “Confirm” icon (D)), or rejected (by pressing the “Exit” icon (E)).
Once the reset has been performed, the ECU will be associated with the motorcycle's throttle body. Replacement of the throttle body, the ECU or the wiring must always be immediately followed by a new reset procedure.
 
Adjusting the idle speed
 Notes
a
b
 
Connect the inserts of the exhaust gas analyser code 88713.1010 to the outlets on the exhaust pipes using the fittings (19).
Make sure that the butterfly valve race is seated against the stop screw when the throttle twistgrip is fully closed.
Make sure that the throttle cable freeplay is correctly adjusted.
Reset the TPS to zero as described in the paragraph “Resetting the throttle position sensor (TPS)” in this section.
Check:
-
that the throttle angle value read by the DDS tester with the engine switched off is 2.6° ±0.1; if not, repeat the procedure “Resetting the throttle position sensor (TPS)”;
-
 
Start the engine and wait for the coolant temperature to reach 75 °C.
When the coolant temperature exceeds 75 °C, start the adjustment operations described below, bearing in mind that on completion of the adjustment, the coolant temperature must not exceed 90 °C.
 Warning
If the engine is shut off, before proceeding with adjustment of the CO level, wait a minute after restarting for the enrichment phase to finish (Crank time).
 
Check the CO level for both cylinders is within the range 0.4% to 1.4%.
If so, proceed with the operation to check the rpm.
 
Checking the average rpm read by the DDS:
A
if the average reading is between 1500 and 1600 rpm (1550±50 rpm), the adjustment is correct;
B
should the average engine speed be less than 1500 rpm, open the bypass screws (20) 1/8 of a turn at a time, until the engine speed is within the range indicated above; if the average engine speed is greater than 1600 rpm, check that there is no air seepage under the butterfly valve and that there are no cracks or cuts in the intake manifold or stepper pipes etc.
 
 Warning
In any event, the bypass screws of the two cylinders must not be opened by more than 2.5 turns from the fully closed position.
Actions to be taken if the idle speed adjustment procedure is not successful
1
2
-
-
3
 Warning
Idle speed adjustment takes priority over balancing the vacuum pressures downstream of the butterfly valve. Differences in pressure between the horizontal and vertical cylinder are therefore acceptable, provided that the idle speed is adjusted correctly.
 
-
If you are unable to reach the desired idle speed setting, try reducing the vacuum differential downstream of the butterfly valve as described in the following paragraph “Throttle body balancing” in this section;
-
Throttle body balancing
Connect the Measurement Module cable (3) to the Measurement Module connector on the DDS tester as described in the paragraph “Description of the Ducati Diagnostic System instrument”.
Connect the vacuum/pressure pipes (6) to the connectors (A) and (C) of cable (3) and connect the fittings (7) to the pipes.
Switch on the DDS tester; see the paragraph “Tester power supply”.
Enter the “Measurement module” function. Press the “Cylinder synchronisation” icon.
The socket to which the Measurement Module cable (3) is to be connected is indicated on the screen with a capital letter: A, B or C. Remove the screws (21) from the cylinder heads and install the fittings (7) in their place.
Open both bypass screws (20) by one turn from the fully closed position.
 Warning
Press the “Reset” icon (G), then connect the sensors (4) and (5) to connectors (A) and (C) of the cable (3) and to the vacuum/pressure pipes (6).
 
Press the “Start” icon to begin the cylinder pressure measurement procedure.
The onscreen indicator light (E) will turn red when the function is active.
Start the engine.
The values may be displayed in two different ways: in numerical form or in graphic form; to select the desired display type, press the “Value display” icon (F).
The values can be reset by pressing the “Reset” icon (G).
To adjust the balance (within the tolerance range of 260 mbar to 270 mbar), turn the bypass screws (20) until the two lines on the graph coincide, if in graphic mode, or until identical numerical values are displayed, if in numerical mode.
Correct balance is obtained when the two lines of the graph are very close together or when the two values are within the specified tolerance range.
Checking the engine oil pressure
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
To measure the pressure of the lubrication circuit, use the engine oil pressure test point (19) as described below.
 
Disconnect the wiring connector (A) and remove the pressure switch (19), taking care to recover the seal.
Insert the fitting (9) into the connection on the hose (12), interposing the two copper sealing washers (20). Insert the fitting (9) of the pipe (12) in the threaded hole (M10x1 mm) of the right crankcase cover and screw it fully home. Refit the pressure switch (19) on the fitting (9) along with its seal, and reconnect the wiring connector (A).
Connect the pressure sensor (5) to the pipe (12) to transform the pressure signal into an electrical signal.
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (Measurement Module) (3) to the measurement module connector (B) on the DDS tester (1).
Connect the pressure sensor (5) to socket (A) or (C) of the cable (3).
On the DDS tester (1), select the “Measurement module” function by pressing the corresponding icon; then press the “Pressure Test” icon (D) followed by the “Start” icon (E).
The socket to which the cable (Measurement Module) (3) is to be connected is indicated on the screen with a capital letter: A, B or C.
Start the engine.
The values may be displayed in three different ways: in one numeric form and in two graphic forms; to select the desired display type, press the “Value display” icon.
The measured value is indicated alongside the letter (A) or (C) identifying the cable used for the measurement: i.e. if you used connector (A) of the cable (3), the value measured will displayed next to the letter (A) on the screen.
Oil pressure test values:
Warm engine
(Minimum oil temperature = 80 °C)
1100 to 1300 rpm
greater than 0.8 bar
3500 to 4000 rpm
greater than 4 bar
 Important
The maximum pressure must never exceed 6.0 bar.
 
Excessively high pressure may indicate that the relief valve is stuck. Excessively low pressure, on the other hand, may be caused by the relief valve being stuck in the open position, the relief valve spring being too weak, or a faulty oil pump. Other causes are excessively worn seals and gaskets or a badly worn engine.
 
Remove the tool and refit the pressure switch (19) along with its seal. Tighten the pressure switch to the specified torque (Sect. C 3, Engine torque settings).
Reconnect the electrical system connector (A) to the pressure switch.
Disconnect the DDS tester.
Cylinder compression test
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
Engine performance is directly correlated to the pressure that can be measured in the combustion chambers of the two cylinders. Excessive or insufficient pressure, or an excessive difference between the two cylinders, will result in a reduction in engine performance and can lead to component failure.
 
Run the engine so that it warms up to the point that the fan is tripped at least once.
Open the throttles completely.
Remove the HT leads (19), unscrewing the nuts (20) of both spark plugs.
Remove the spark plug from the cylinder to be tested.
Connect the HT lead to earth to prevent sparking.
Screw the cylinder compression fitting (11) into the spark plug bore.
Connect the pressure sensor (5) to the cable (11).
Switch on the DDS tester (1); see paragraph entitled “Connection to motorcycle”.
Connect the power and diagnostics cable (Measurement Module) (3) to the measurement module connector (B) on the DDS tester (1).
Connect the pressure sensor (5) to socket (A) or (C) of the cable (3).
 Notes
Measure the compression on one cylinder at a time.
On the DDS tester (1), select the “Measurement module” function by pressing the corresponding icon; then press the “Cylinder Compression” icon (D) followed by the “Start” icon (E).
The socket to which the cable (Measurement Module) (3) is to be connected is indicated on the screen with a capital letter: A, B or C.
Turn over the engine with the starter motor until the pressure stops rising.
Check the pressure in each cylinder:
-
standard value: 11 to 12 bar;
-
-
An excessively high pressure value can be caused by:
-
An excessively low pressure value can be caused by:
-
-
-
-
-
 
Refit the sparkplugs, position the HT leads (19) in their respective housings and tighten the nuts (20) to the specified torque (Sect. C 3, Frame torque settings).
 
Fuel pressure test
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
Lift the fuel tank (Sect. L 2, Removal of the fuel tank), leaving it connected to the fuel hoses.
Slightly raise the fuel tank and place a pad underneath it so as to be able to access the fittings on the flange.
Remove the fuel feed hose (19).
Take the fuel pressure pipe test (17) and connect one end (D) to the outlet fitting on the tank and the other end (E) to the fuel feed hose (19) in this way, the fuel pressure can be measured at the test outlet (F).
Connect the pressure sensor (5) to the test outlet (F) of the pipe (17) to transform the pressure signal into an electrical signal.
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (Measurement Module) (3) to the measurement module connector (E) on the DDS tester (1).
Connect the pressure sensor (5) to socket (A) or (C) of the cable (3).
On the DDS tester (1), select the “Measurement module” function by pressing the corresponding icon; then press the “Pressure Test” icon (F) followed by the “Start” icon (G).
The socket to which the cable (Measurement Module) (3) is to be connected is indicated on the screen with a capital letter: A, B or C.
The values may be displayed in three different ways: in one numeric form and in two graphic forms; to select the desired display type, press the “Value display” icon (H).
The measured value is indicated alongside the letter (A) or (C) identifying the cable used for the measurement: i.e. if you used connector (A) of the cable (3), the value measured will displayed next to the letter (A) on the screen.
The maximum pressure must be 3 bar (nominal).
On completion of the test, remove all the components of the test instrument and refit the fuel feed hose (19).
Refit the fuel tank (Sect. L 2, Refitting the fuel tank).
 
Immobilizer override procedure
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
If the immobilizer system does not work, there is an emergency procedure for starting the engine, by entering the secret code with the aid of the DDS tester.
 
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (2) to the diagnostics connector (H) on the tester and to the diagnostics socket (L) on the motorcycle.
Enter the general functions menu by pressing the icon “Menu 1” (A).
Press the “Select vehicle” icon and, on the next screen, press the “Select motorcycle” icon; select the motorcycle model and confirm, then select the version and confirm.
Press the icon “Select system” to display a list of the bike’s systems that can be analysed.
Select “Engine electronics” and press the “Confirm” icon (B). Next, press the “Self-diagnosis” icon to access the corresponding function.
The DDS tester will interrogate the electronic control unit and display the parameters analysed with their relative values.
 Notes
Make all connections with the motorcycle ignition key in the OFF position.
 
Press the “Actuators” icon (C) to display the actuators and other components connected to the ECU.
Select the option “Immobilizer Override” and then press the icon “Apply” (D).
A screen will appear in which you can enter the 5 digit secret code. Use the red arrows (E) and (F) to enter each digit: after entering each digit, press the “Confirm” icon (B).
One the entire code has been entered, press the “Confirm” icon (B) again.
On completion of the operation, the message “Was the operation completed successfully?” will appear; press “Confirm”.
If any problems were encountered during the operation, the tester will display the relative error messages: each message must be confirmed by pressing the “Confirm” icon, or rejected by pressing the “Exit” icon (G).
Disconnect the tester.
 
Guided diagnosis
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
The DDS tester guides the operator step-by-step through the various diagnostic procedures, providing descriptions and documentation for motorcycle components, wiring diagrams for the electronic systems and information on the locations of specific components.
 
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (2) to the diagnostics connector (F) on the tester and to the diagnostics socket (G) on the motorcycle.
Enter the general functions menu by pressing the icon “Menu 1” (A).
Press the “Select vehicle” icon and, on the next screen, press the “Select motorcycle” icon; select the motorcycle model and confirm, then select the version and confirm.
Press the icon “Select system” to display a list of the bike’s systems that can be analysed.
Select “Engine electronics” and press the “Confirm” icon (B).
Press the “Guided diagnosis” icon (C) to access the corresponding function.
A series of screens are displayed indicating the operations required for correct diagnosis.
To determine whether the system has any internal problems, you can access the “Self-diagnosis” function by pressing the corresponding icon. If any errors are present, the symbol (D) will be displayed. To determine the type of errors present, press the “Errors” icon (E). Once errors have been detected, you can then resolve them through the guided diagnosis procedure; press the “Guided Diagnosis” icon (C).
The DDS tester will interrogate the electronic control unit and display the parameters analysed with their relative values.
 
Testing the battery charging system
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
You can determine the engine rpm required for the alternator to produce sufficient current to charge the battery, power the injection/ignition system and all the electrical equipment on the motorcycle. When applied to a cable, the ammeter clamp (18) detects the magnetic field generated by the current passing through that cable.
 
Switch on the DDS tester (1); see paragraph entitled “Tester power supply”.
Connect the power and diagnostics cable (Measurement Module) (3) to the measurement module connector (D) on the DDS tester (1).
Connect the ammeter clamp to the connector (E) of the power and diagnostics cable (Measurement Module) (3).
 Warning
The ammeter clamp must not be connected to wires through which electrical current is flowing.
 
Apply the ammeter clamp to the battery positive terminal lead with the arrow on the clamp pointing towards the battery positive terminal (+).
On the DDS tester (1), select the “Measurement module” function by pressing the corresponding icon; then press the “Ammeter” icon (F) followed by the “Start” icon.
The socket to which the cable (Measurement Module) (3) is to be connected is indicated on the screen with a capital letter: A, B or C.
If the measured current is a positive quantity, this means that alternator is powering all the electrical loads and charging battery at the same time. If the current has a negative sign, this means that the charging system is not able to power the electrical loads and a significant amount of the current required must be supplied by the battery, which is therefore discharging.
 Important
If polarity is reversed when clamping the ammeter onto the cable, the sign of the readings will also be reversed, giving rise to incorrect diagnosis.
 
Deactivating the “service” indication on the instrument panel
The message “SERV” is displayed on the instrument panel, indicating that the motorcycle should be serviced in accordance with the programmed maintenance plan. This indication is activated after the first 1000 km and thereafter at intervals of 12000 km.
 
After the scheduled service has been carried out, the indication must be switched off as follows:
 Notes
The on-screen icons used during this procedure are explained in a table at the end of this section.
 
Switch on the DDS tester; see the paragraph “Tester power supply”.
Connect the power and diagnostics cable (2) to the diagnostics connector (A) on the tester and to the diagnostics socket (E) on the motorcycle.
Enter the general functions menu by pressing the icon “Menu 1” (B).
Press the “Select vehicle” icon and, on the next screen, press the “Select motorcycle” icon; select the motorcycle model and confirm, then select the version and confirm.
Press the “Select system” icon.
A list of the motorcycle’s systems that can be analysed will appear on the display
Select “Engine electronics”.
 
Press the “Confirm” icon (C). Next, press the “Self-diagnosis” icon to access the corresponding function.
The DDS tester will interrogate the electronic control unit and display the parameters analysed with their relative values.
Press the “Settings” icon to display the special parameters.
Select the option “Service light OFF” and then press the “Apply” icon.
On completion of the operation, the message “Was the operation was completed successfully?” will appear; press “Confirm” (C).
If any problems were encountered during the operation, the tester will display the relative error messages: each message must be confirmed, (by pressing the “Confirm” icon (C)), or rejected (by pressing the “Exit” icon (D)).
 Notes
Once the “service” indication has been reset with the DDS tester, set the ignition switch to OFF and wait for at least 30 seconds before switching it ON again.
 
Icons table
 
Menu 1